Skip to Content
✉️ Email: pdm.alpha@gmail.com 📍 Dhaka, Bangladesh
📞 Phone: +880 1795740741 | Contact Us
🔍

Global Product Search

No matching products found across the site.

Sensepoint XCD Gas Detector
Honeywell

Sensepoint XCD Gas Detector

A comprehensive gas detector for monitoring flammable, toxic or oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors.


IP66
Protection
12 - 32 VDC
Voltage
-40℃
Min Temp

Transmitter provides comprehensive monitoring of combustible, toxic and Oxygen gas hazards in potentially explosive atmospheres - indoors and outdoors.

Sensepoint XCD

Product Overview

Sensepoint XCD now has remote monitoring capabilities for its toxic and Oxygen sensors. Its remote capability is designed to offer excellent flexibility of use and is an ideal solution for hard-to-reach locations or areas where the transmitter needs to be separate from the sensor. With remote toxic and Oxygen sensor mounting of up to 100 feet (30m) away from the transmitter, Sensepoint XCD provides a robust monitoring solution even in challenging environments where detection is difficult, including applications where the point of detection is in an area that is not easily accessible or where the detector would not be visible, like in high or low level concealed areas or outside a room being monitored.

Sensepoint XCD is easy to use. The sensor simply plugs into the bottom of the transmitter and the transmitter automatically configures itself accordingly. Users can modify detector operation using the LCD and magnet switches without ever needing to open the unit. This enables one-man, non-intrusive operation and reduces routine maintenance time and costs.

A tri-color backlit LCD clearly indicates the unit's status at a glance, even from a distance. A steady green backlight indicates normal operation, flashing yellow indicates fault and flashing red indicates an alarm.

All detectors are supplied pre-configured and include two programmable alarm relays, one programmable fault relay as well as an industry standard 4-20mA output (sink or source selectable) and MODBUS communication. The scale, range, relay operation, alarm set point and electronic tag number of the detector can be adjusted using the transmitter's LCD and non-intrusive magnetic switches. Outputs are automatically inhibited during adjustment, thereby reducing the risk of false alarm at the control panel during maintenance.

Additional Features and Benefits

All-In-One Gas Monitoring Solution
  • Flammable (catalytic or infrared), toxic and oxygen versions available
  • Serves new/retrofit, indoor/outdoor applications
  • Stainless steel or aluminum explosion-proof housing options
  • IP66 as standard
Proven and Reliable Sensor Technology
  • Surecell™ electrochemical sensors
  • Poison immune infrared sensors
  • Poison resistant catalytic bead sensors
  • Long life sensors
Global Approvals
  • US and Latin America, European, Canadian and Asian
  • Compliant with UL, INMETRO, ATEX, IECEx, CSA, KTL, PA, GB and CCCF standards
Easy to Use
  • User friendly and intuitive tri-color backlit display with digits, bar graph and icons
  • Fully configurable via magnetic switches
  • Optional remote sensor mounting
  • Selectable sink or source 4-20mA output
  • Auto-inhibit during maintenance
  • MODBUS communications for remote diagnostics/configuration
Cost Effective & Simple Installation
  • Common transmitter platform with minimal training required
  • Non-intrusive, one-man operation with plug-in sensor replacement
  • Plug-in display module removes to give access to terminal area
  • Integral mounting bracket & plate attaches to surface, horizontal or vertical piping
Fire and Gas Consultancy Services

Even the best products deserve expert maintenance!

Elevate your gas detectors' potential with expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion. Explore our fixed, portable, and high-tech support services now!

Technical Specifications

Overview
Brand Honeywell, Notifier
Product Type Industrial Gas
Features
Sub-Category Gas Detection Sensors & Transmitters
Relay Included Yes
Dimensions & Weight
Weight Range 316 Stainless Steel: 11 lbs | Aluminium Alloy LM25: 4.4 lbs
Operating Characteristics
Minimum Temperature -40℃
Material Specifications
Material 316 Stainless Steel
Enclosure Material Epoxy Painted Aluminium Alloy ADC12 or 316 Stainless Steel
Technical Specs
Relay Output Config. 3 x 5A @250 VAC
Number of Relays 3
Mounting Mounting Plate
Conduit Entries (2) 3/4 in NPT
Communication Modbus RTU, RS485
Standards & Certifications
Ingress Protection IP66
Electrical Specifications
Power Consumption Catalytic: 4.9W | Electrochemical Cells: 3.7W | IR: 3.7W
Operating Voltage 12 to 32 VDC
Others
Industry Commercial Buildings, Energy, Manufacturing

Product Resources & Downloads

Download the latest technical manuals, brochures, and certification documents for the Sensepoint XCD directly below.

Part Numbers & Configurations

Below is the complete list of all 47 available configurations and orderable part numbers for the Sensepoint XCD. Please reference these when requesting a quote.

Part Number Description
SPXCDALMB1 Sensepoint XCD, CO2, IR, 0-2%VOL, Aluminium Alloy, M20 Entry
SPXCDALMCX Gas Sensor: CO: 0 to 300ppm: LM25: M20: ATEX: IECEx: KTL: PA: GB
SPXCDALMFX SENSEPOINT XCD GAS DETECTOR
SPXCDALMG1 Sensepoint XCD, Hydrogen, 0-1000ppm, Aluminium Alloy, M20 Entry
SPXCDALMG1M XCD Gas Detector, 4 to 20 mA and Modbus output, ATEXIECExAsian approvals, 2 x M20 entries, painted LM25, includes hydrogen EC sensor cartridge 0 to 1000ppm, includes nylon weather protection
SPXCDALMHX XCD Gas Detector: 4 to 20 mA output: ATEXIECExAsian approvals: 2 x M20 entries: painted LM25: includes hydrogen sulfide EC sensor cartridge 0 to 50ppm: user selectable FSD between 10 and 100ppm (1 ppm resolution): includes nylon weather protection
SPXCDALMO1 ATEX XCD O2 25.0%Vol LM25 M20
SPXCDALMR1 XCD M20 ALU FLAM IR (II) 100%LEL CH4
SPXCDALMRX Triple IR flame detector Suitable for ATEX zone 222; FM 3611 Class 1, 2&3 Div2 EN54-10 (HIGH sensitivity) certificate (pending *) FM3260 approval (pending*). Red Housing.
SPXCDALMTXF Sensepoint XCD Flam and IR Tx, ATEX, LM2
SPXCDALMTXFM XCD IR & Flammable Transmitter (without sensor), 4 to 20 mA and Modbus output, ATEXIECExAsian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection
SPXCDALMTXO XCD O2 Transmitter (without sensor), 4 to 20 mA output, ATEXIECExAsian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection
SPXCDALMTXOM XCD O2 Transmitter (without sensor), 4 to 20 mA and Modbus output, ATEXIECExAsian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection
SPXCDALMTXT XCD Toxic Transmitter (without sensor), 4 to 20 mA output, ATEXIECExAsian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection
SPXCDALMTXTM XCD Toxic Transmitter (without sensor), 4 to 20 mA and Modbus output, ATEXIECExAsian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection
SPXCDASMB1 Gas Sensor: CO2: 316SS: M20: ATEX: IECEX: AP
SPXCDASMCX XCD ATEXIECEXAP M20 316SS CO PPM
SPXCDASMFX Gas Sensor: 0 to 100% Level: 316SS: M20: ATEX: IECEX: AP
SPXCDASMG1 Gas Sensor: H2: 0-1000ppm: 316SS: M20: ATEX: IECEX: AP
SPXCDASMHX 1CD ATEXIECEXAP M20 316SS H2S PPM
SPXCDASMO1 Gas Sensor: O2: 0 to 25%: 316SS: M20: ATEX: IECEX: AP
SPXCDASMRX Gas Sensor: CH4: IR: 316SS: M20: ATEX: IECEX: AP
SPXCDASMTXF Sensepoint XCD Flam and IR Tx, ATEX, SS3
SPXCDASMTXFM XCD IR & Flammable Transmitter (without sensor), 4 to 20 mA and Modbus output, ATEXIECExAsian approvals, 2 x M20 entries, painted 316SS
SPXCDASMTXO XCD O2 Transmitter (without sensor), 4 to 20 mA output, ATEXIECExAsian approvals, 2 x M20 entries, painted 316SS, includes nylon weather protection
SPXCDASMTXOM XCD O2 Transmitter (without sensor), 4 to 20 mA and Modbus output, ATEXIECExAsian approvals, 2 x M20 entries, painted 316SS
SPXCDASMTXT XCD Toxic Transmitter (without sensor), 4 to 20 mA output, ATEXIECExAsian approvals, 2 x M20 entries, painted 316SS, includes nylon weather protection
SPXCDASMTXTM XCD Toxic Transmitter (without sensor), 4 to 20 mA and Modbus output, ATEXIECExAsian approvals, 2 x M20 entries, painted 316SS
SPXCDULNG1 XCD Gas Detector, includes hydrogen EC sensor cartridge 0 to 1000ppm
SPXCDULNRXM ULINMETRO approved SP XCD Flammable Methane (CH4) IR 0-100% LEL (20 to 100% LEL, 10% LEL) with LM25, 34NPT with Modbus
SPXCDULNTXF XCD IR & Flammable Transmitter (without sensor), 4 to 20 mA output, ULc-ULINMETRO, 2 x 34 NPT entries, painted LM25, includes nylon weather protection
SPXCDULNTXFM XCD IR & Flammable Transmitter (without sensor), 4 to 20 mA and Modbus output, ULc-ULINMETRO, 2 x 34 NPT entries, painted LM25, includes nylon weather protection, includes nylon weather protection
SPXCDULNTXO XCD O2 Transmitter (without sensor), 4 to 20 mA output, ULc-ULINMETRO, 2 x 34 NPT entries, painted LM25, includes nylon weather protection
SPXCDULNTXOM XCD O2 Transmitter (without sensor), 4 to 20 mA and Modbus output, ULc-ULINMETRO, 2 x 34 NPT entries, painted LM25, includes nylon weather protection
SPXCDULNTXT XCD Toxic Transmitter (without sensor), 4 to 20 mA output, ULc-ULINMETRO, 2 x 34 NPT entries, painted LM25, includes nylon weather protection
SPXCDULNTXTM XCD Toxic Transmitter (without sensor), 4 to 20 mA and Modbus output, ULc-ULINMETRO, 2 x 34 NPT entries, painted LM25, includes nylon weather protection
SPXCDUSNTXF XCD IR & Flammable Transmitter (without sensor), 4 to 20 mA output, ULc-ULINMETRO, 2 x 34 NPT entries, painted 316SS, includes nylon weather protection
SPXCDUSNTXFM XCD IR & Flammable Transmitter (without sensor), 4 to 20 mA and Modbus output, ULc-ULINMETRO, 2 x 34 NPT entries, painted 316SS, includes nylon weather protection
SPXCDUSNTXO XCD O2 Transmitter (without sensor), 4 to 20 mA output, ULc-ULINMETRO, 2 x 34 NPT entries, painted 316SS, includes nylon weather protection
SPXCDUSNTXOM XCD O2 Transmitter (without sensor), 4 to 20 mA and Modbus output, ULc-ULINMETRO, 2 x 34 NPT entries, painted 316SS, includes nylon weather protection
SPXCDUSNTXT XCD Toxic Transmitter (without sensor), 4 to 20 mA output, ULc-ULINMETRO, 2 x 34 NPT entries, painted 316SS, includes nylon weather protection
SPXCDUSNTXTM XCD Toxic Transmitter (without sensor), 4 to 20 mA and Modbus output, ULc-ULINMETRO, 2 x 34 NPT entries, painted 316SS, includes nylon weather protection
SPXCDXSCXSS Carbon Monoxide 0-300ppm (100 to 1000ppm: 100ppm)
SPXCDXSG1SS Hydrogen 0-1000ppm only
SPXCDXSHXSS Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm: 1ppm)
SPXCDXSNXSS Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm: 5ppm)
SPXCDXSO1SS Oxygen 25.0% vv only